The Cleveland Play House
Production Department
8500 Euclid Avenue
Cleveland, OH 44106
p: 216-795-7000
f: 216-795-7005
|
|
 |
General
- If it looks or sounds funny - WHY?
- “One of these things is not like the other”
- Pay attention, look for things that aren’t as they should be. Write it down.
Policy
A user shall not attempt a procedure he is not competent to perform. The Production Manager, Technical Director or Head Flyman will determine competency.
Each theater has a clipboard with a lineset schedule for the current show and a maintainace log.
Skills
- Knots
- Counter Weight Systems Operation
- Basic flying
- Run aways - YELL “RUN AWAY” not “heads”, do not try to stop the line.
- Spikes - how we set them
- Flying sets in and out
- The rope lock is not a brake
- Loading and unloading
- communication - rail to deck
- spreader plates, locking collars
- How to load
- Ideal situation - pipe in, arbor at loading bridge
- Out of balance situation - the Wrap
- Chain motor
- Double purchase
- Kicking Loft Blocks
- Spot lines
- Placing Loft blocks
- Tying Off
- Spiking
- Assembly of hardware
- Drury Main Curtain
- Emergency Stop
- Basic Operation
- Trim setting
- Fire Curtain
- How to manual operate
- How to Emergency release
- Drury - pull ring
- Bolton - electric
- How to reset
|